CALB - STATION INSTRUMENTATION
2. TERRAscope Seismograph Network:   [ TS ]
DATES OF OPERATION:  	11 Jan 1994 to 22 Jul 1995 
SEISMOMETER TYPE and ADC:
Strekeisen Model STS-2/VBB 3 component system.  Kinemetrics Model FBA-23 
for all low-gain channels.  ADC is Quanterra Model Q-680.
DIGITAL FORMAT:
24 bit integer data words for all components.  Range: +8,388,607 to -8,388,608 counts.
EVENT DETECTOR ALGORITHM:  
The Murdock event detector (Murdock, 1991) is used for all short period data.
Click on any of the following items for further information.
COMMENTS:
CALB was a temporary station located near the epicenter of the 17 Jan 1994 
Southern California earthquake to collect aftershock data. It is still in use.