BAR Channel Data
Channel Data:
Channels Sampling Rate Sensitivities
BHZ 20 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
BHN 20 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
BHE 20 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
EHZ 80 sps event triggered 5.99000e+08 C/m/s @ 5.00 Hz
EHN 80 sps event triggered 5.99000e+08 C/m/s @ 5.00 Hz
EHE 80 sps event triggered 5.99000e+08 C/m/s @ 5.00 Hz
ELZ 80 sps event triggered 2.14000e+05 C/m/s2 @ 5.00 Hz
ELN 80 sps event triggered 2.14000e+05 C/m/s2 @ 5.00 Hz
ELE 80 sps event triggered 2.14000e+05 C/m/s2 @ 5.00 Hz
LHZ 1 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
LHN 1 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
LHE 1 sps continuous 5.99000e+08 C/m/s @ 0.02 Hz
VHZ 0.1 sps continuous 2,39000e+09 C/m/s @ 0.02 Hz
VHN 0.1 sps continuous 2.39000e+09 C/m/s @ 0.02 Hz
VHE 0.1 sps continuous 2.39000e+09 C/m/s @ 0.02 Hz
UHZ .01 sps continuous 2.39000e+09 C/m/s @ 0.003 Hz
UHN .01 sps continuous 2.39000e+09 C/m/s @ 0.003 Hz
UHE .01 sps continuous 2.39000e+09 C/m/s @ 0.003 Hz
UMZ .01 sps continuous 2.04470e+08 C/m/s @ 2.0e-05 Hz
UMN .01 sps continuous 2.08140e+08 C/m/s @ 2.0e-05 Hz
UME .01 sps continuous 2.16010e+08 C/m/s @ 2.0e-05 Hz
EDO 100 sps event triggered 0.158 C/Pascal @ 0.1 to 25.0 Hz
LDO 1.0 sps continuous 0.158 C/Pascal @ 0.0 to 0.25 Hz
LEB 1.0 sps continuous 3276 C/V (DC Volt. to Battery)
LKI 1.0 sps continuous 327.7 C/¡C (Temp. sensor Mod. AD590)