TLY Channel Data


Channel Data:  
Caution:  These sensitivities assume nominal values for all seismometer generator 
constants, amplifiers and filters, and analog-to-digital converters and are 
accurate only to approximately 5%.  For actual response see SEED information 
distributed with data.

Channels        Sampling Rate           	Sensitivities
BHZ/BHN/BHE     20 sps continuous       	5.2754e+08 C/m/s @ 0.02 Hz
BLZ/BLN/BLE     20 sps continuous       	1.4864e+07 C/m/s @ 0.02 Hz
EHZ/EHN/EHE     200 sps event triggered 	6.7365e+08 C/m/s @ 10 Hz
ELZ/ELN/ELE     200 sps event triggered 	1.0513e+07 C/m/s @ 10 Hz
LHZ/LHN/LHE	1 sps continuous		2.1090e+09 C/m/s @ 0.01 Hz
LLZ/LLN/LLE	1 sps continuous		5.9428e+07 C/m/s @ 0.01 Hz
VHZ/VHN/VHE     0.1 sps continuous      	4.0291e+09 C/m/s @ 0.005 Hz
VMZ/VMN/VME 	0.1 sps continuous		1.1718e+05 C/m/s @ 0.005 Hz