RPN Channel Data


Channel Data: 
Caution:  These sensitivities assume nominal values for all seismometer generator
constants, amplifiers and filters, and analog-to-digital converters and are
accurate only to approximately 5%.  For actual response see SEED information
distributed with data.

Channels        Sampling Rate           	Sensitivities
BHZ/BHN/BHE     20 sps event triggered       	4.7695e+08 C/m/s @ 0.02 Hz
BLZ/BLN/BLE     20 sps event triggered       	7.4524e+06 C/m/s @ 0.02 Hz      
LHZ/LHN/LHE	1 sps continuous		1.8820e+09 C/m/s @ 0.01 Hz
LLZ/LLN/LLE	1 sps continuous		2.9407e+07 C/m/s @ 0.01 Hz
MHZ/MHN/MHE	5 sps continuous		4.7695e+08 C/m/s @ 0.02 Hz
MLZ/MLN/MLE	5 sps continuous		7.4524e+06 C/m/s @ 0.02 Hz
VGZ		0.1 sps continuous		1.4119e+08 C/m/s @ 0.005 Hz
VHZ/VHN/VHE     0.1 sps continuous      	4.6215e+09 C/m/s @ 0.005 Hz
VMZ/VMN/VME 	0.1 sps continuous		1.1718e+05 C/m/s @ 0.005 Hz