GAR Channel Data


Channel Data: 
Caution:  These sensitivities assume nominal values for all seismometer generator
constants, amplifiers and filters, and analog-to-digital converters and are 
accurate only to approximately 5%.  For actual response see SEED information 
distributed with data.

Channels        Sampling Rate           Sensitivities
BHZ/BHN/BHE     20 sps continuous       4.5967e+08 C/m/s @ 0.02 Hz
BLZ/BLN/BLE     20 sps continuous       7.1823e+06 C/m/s @ 0.02 Hz
LHZ/LHN/LHE	1 sps continuous	1.8335e+09 C/m/s @ 0.01 Hz
LLZ/LLN/LLE	1 sps continuous	2.8649e+07 C/m/s @ 0.01 Hz
VHZ/VHN/VHE     0.1 sps continuous	3.5143e+09 C/m/s @ 0.005 Hz