COCO - STATION INSTRUMENTATION
2. Global Seismograph Network - GSN:
DATES OF OPERATION: 15 Dec 1996 to 22 May 1997.
SEISMOMETER TYPE AND ADC:
Teledyne Brown Model KS-54000. A borehole three component system for
broadband long period, and very long period channels recorded at 20 sps,
1 sps, and 0.1 sps respectively. Guralp Systems model CMG-3T 3-component
seismometer for short-period channels continuously recorded at 40 samples
per second (channel designator sh*). Streckeisen Model STS-2 triaxial
seismometer for short period channels recorded at 40 sps continuous mode
(channel designator eh*). IDA MK7 data acquisition system.
CALIBRATION EPOCHS: 1996, 350 - 1997, 142
DIGITAL FORMAT:
32 bit integer data words for all broadband (20 sps), long period (1 sps), very
long period (.1 sps), and short period (40 sps) channels.