ASCN Channel Data


Channel Data:
Caution: These sensitivities assume nominal values for all seismometer generator
constants, amplifiers and filters, and analog-to-digital converters and are 
accurate only to approximately 5%.  For actual response see SEED information 
distributed with data.

Channels        Sampling Rate           Sensitivities
BHZ/BHN/BHE     20 sps continuous       1.3873e+09 C/m/s @ 0.02 Hz
LHZ/LHN/LHE	1 sps continuous	1.0421e+09 C/m/s @ 0.01 Hz
SHZ/SHN/SHE	40 sps continuous	1.3442e+09 C/m/s @ 5 Hz
SLZ/SLN/SLE	40 sps continuous	2.0878e+07 C/m/s @ 5 Hz
VHZ/VHN/VHE     0.1 sps continuous      6.2173e+08 C/m/s @ 0.005 Hz
VMZ/VMN/VME	0.1 sps continuous	1.6077e+06 C/m/s @ 0.005 Hz