ARU Channel Data


Channel Data:
Caution:  These sensitivities assume nominal values for all seismometer generator 
constants, amplifiers and filters, and analog-to-digital converter and are accurate
only to approximately 5%.  For actual response see SEED information distributed 
with data.

Channels        Sampling Rate           	Sensitivities
BHZ/BHN/BHE     20 sps continuous       	5.3779e+08 C/m/s @ 0.02 Hz
BLZ/BLN/BLE     20 sps continuous       	1.5221e+07 C/m/s @ 0.02 Hz
EHZ/EHN/EHE	200 sps event triggered 	2.5185e+09 C/m/s @ 10 Hz
ELZ/ELN/ELE	200 sps event triggered 	4.1152e+07 C/m/s @ 10 Hz
LHZ/LHN/LHE     1 sps continuous		2.1424e+09 C/m/s @ 0.01 Hz
LLZ/LLN/LLE	1 sps continuous		6.6632e+07 C/m/s @ 0.01 Hz    
VHZ/VHN/VHE     0.1 sps continuous		4.0818e+09 C/m/s @ 0.005 Hz
VMZ/VMN/VME	0.1 sps continuous		1.1575e+05 C/m/s @ 0.005 Hz