ABKT Channel Data


Channel Data:  
Caution:  These sensitivities assume nominal values for all seismometer generator 
constants, amplifiers and filters, and analog-to-digital converters and are 
accurate only to approximately 5%.  For actual response see SEED information 
distributed with data.

Channels        Sampling Rate                   Sensitivities
BHZ/BHN/BHE     20 sps continuous               5.4005e+08 C/m/s @ 0.02 Hz
BLZ/BLN/BLE     20 sps continuous               1.5358e+07 C/m/s @ 0.02 Hz
EHZ/EHN/EHE     200 sps event triggered         6.5318e+08 C/m/s @ 10 Hz
ELZ/ELN/ELE     200 sps event triggered         1.0158e+07 C/m/s @ 10 Hz
LHZ/LHN/LHE     1 sps continuous		2.1548e+09 C/m/s @ 0.001 Hz
LLZ/LLN/LLE	1 sps continuous		6.1280e+07 C/m/s @ 0.001 Hz  
VHZ/VHN/VHE     0.1 sps continuous              4.1106e+09 C/m/s @ 0.005 Hz
VMZ/VMN/VME	0.1 sps continuous		5.8089e+04 C/m/s @ 0.005 Hz