KMI Channel Data

Channel Data:
Channel		Sampling Rate		Sensitivities
ELZ             80 sps event triggered  53687 C/m/s2 @1Hz
ELN             80 sps event triggered  53687 C/m/s2 @1Hz
ELE             80 sps event triggered  53687 C/m/s2 @1Hz
HHZ		80 sps event triggered  8.3886e+09 C/m/s
HHN             80 sps event triggered  8.3886e+09 C/m/s
HHE             80 sps event triggered  8.3886e+09 C/m/s
SHZ		40 sps event triggered  8.3886e+09 C/m/s @5Hz
SHN		40 sps event triggered  8.3886e+09 C/m/s @5Hz
SHE		40 sps event triggered  8.3886e+09 C/m/s @5Hz
BHZ		20 sps continuous	1.494e+08 C/m/s @0.02Hz	
BHN		20 sps continuous	1.494e+08 C/m/s @0.02Hz
BHE		20 sps continuous	1.494e+08 C/m/s @0.02Hz
LHZ		1 sps continuous	6.033e+08 C/m/s @0.02Hz
LHN		1 sps continuous	6.033e+08 C/m/s @0.02Hz
LHE		1 sps continuous	6.033e+08 C/m/s @0.02Hz
LLZ		1 sps continuous	53687 C/m/s2 @1Hz
LLN		1 sps continuous	53687 C/m/s2 @1Hz
LLE		1 sps continuous	53687 C/m/s2 @1Hz
VHZ		0.1 sps continuous	2.390e+09 C/m/s @0.02Hz
VHN		0.1 sps continuous	2.390e+09 C/m/s @0.02Hz
VHE		0.1 sps continuous	2.390e+09 C/m/s @0.02Hz
UHZ		0.01 sps continuous	5.446e+07 C/m/s @0.003Hz
UHN		0.01 sps continuous	5.446e+07 C/m/s @0.003Hz
UHE		0.01 sps continuous	5.446e+07 C/m/s @0.003Hz